Czech Energy Audit Duty: What the 2026 Law and Decree 183/2026 Mean for Businesses and Lighting

Czech Energy Audit Duty: What the 2026 Law and Decree 183/2026 Mean for Businesses and Lighting

Since 1 January 2026 the Czech energy audit duty depends on energy use: an audit from 2,778 MWh, ISO 50001 from 23,611 MWh. Decree 183/2026 applies from 1 November. What it means for lighting.

6 min de lecture Par Nick CuppensMis à jour le 20.11.2026

Since 1 January 2026 the energy audit duty in the Czech Republic no longer depends on company size but on average annual final energy consumption over the last three calendar years: an audit every 4 years above 2,778 MWh (about 10 TJ) and a certified ISO 50001 system above 23,611 MWh (about 85 TJ). Since 1 November 2026 the new Decree No. 183/2026 Coll. also applies, setting out how the audit is carried out. Lighting is part of the energy use that the audit covers.

In brief
  • The amendment to Act No. 406/2000 Coll. (No. 87/2025 Coll.) applies from 1 January 2026. What counts is the average annual final energy consumption over the last three calendar years.
  • Above 2,778 MWh (about 10 TJ) an energy audit is mandatory every 4 years. Above 23,611 MWh (about 85 TJ) a certified energy management system under ISO 50001 is mandatory.
  • Decree No. 183/2026 Coll. applies from 1 November 2026, replaces Decree No. 140/2021 Coll. and implements Directive (EU) 2023/1791.
  • The fine is up to CZK 5 million (Section 12a of Act No. 406/2000 Coll.); supervision is carried out by the State Energy Inspectorate.
  • Replacing luminaires with LED does not replace the audit. It does reduce the electricity used for lighting.

What applies since 1 January 2026

Average annual final energy consumption (3 years) Obligation for the business Deadline
above 2,778 MWh (about 10 TJ) energy audit every 4 years within 1 year of the obligation arising
above 23,611 MWh (about 85 TJ) implemented and certified energy management system under ISO 50001 within 2 years of the obligation arising

Below the 23,611 MWh threshold a certified ISO 50001 system can replace the audit. If another business owns at least 50% of the capital or voting rights, the consumption of the whole group is added up. For an obligation that arose through the amendment on 1 January 2026, this in practice means a deadline usually by the end of 2026. Please confirm the exact deadline with an energy specialist or the State Energy Inspectorate. The audit may only be carried out by an energy specialist authorised by the Ministry of Industry and Trade (Section 10 of the Act). Audits carried out under the earlier rules remain valid within the transitional periods set by the amendment.

What Decree No. 183/2026 Coll. brings

The decree was issued by the Ministry of Industry and Trade (adopted on 5 October, published on 13 October 2026) and applies from 1 November 2026. It sets out how the average annual final energy consumption is calculated, how an energy management system is implemented, how the audit is carried out and what the written report must contain. Audits started before 1 November 2026 are completed under the previous decree. The pro rata counting of the consumption of linked businesses with a 25 to 50% stake has been abolished; from a 50% stake the full consumption is counted.

Warehouse in Geel lit by LED high bays 100W at 9 m
Warehouse of Taura in Geel lit by LED high bays 100W at a height of 9 m.

What this means for lighting

If the audit is mandatory for your company, it has to include lighting. According to specialist sources, an audit of lighting usually assesses the inventory of luminaires, their wattage and age, actual electricity consumption, compliance with the standard ČSN EN 12464-1 and the saving potential from switching to LED or lighting control.

Worked example: a hall with 40 discharge luminaires of 400W (about 440W with ballast), replaced by 40 LED luminaires of 150W, at 4,000 operating hours per year.

Item Value
Energy saving (440 − 150) W × 40 × 4,000 h ÷ 1,000 = 46,400 kWh per year
Share of the 2,778 MWh threshold 46.4 MWh ÷ 2,778 MWh ≈ 1.7%
Lower electricity cost at CZK 3.50/kWh (example price excl. VAT) about CZK 162,400 per year

The electricity price is an example: please use the price from your own contract. The obligation depends on the consumption of the whole company, not on lighting alone; in this example lighting is about 1.7% of the audit threshold. You can recalculate with your own values in the guide LED Payback Period Calculator. Which LED luminaire replaces which lamp is shown in Replacing HQL, HQI and Sodium Lamps with LED. For planning a hall see LED Lighting for a Commercial Hall, and the general benefits are summarised in Modernising LED Lighting.

LED luminaires for hall refurbishment

Frequently asked questions

Who is subject to the energy audit obligation?

Businesses with an average annual final energy consumption above 2,778 MWh over the last three calendar years. The consumption of all sites, buildings and installations that the business owns or uses for its activities is counted.

By when does the audit have to be completed?

Within one year of the obligation arising. For an obligation that arose through the amendment on 1 January 2026, this usually means the end of 2026. Please confirm the exact deadline with an energy specialist.

What fine is possible?

Up to CZK 5,000,000 under Section 12a of Act No. 406/2000 Coll. Supervision is carried out by the State Energy Inspectorate.

Does replacing luminaires with LED replace the energy audit?

No. The audit covers the total energy consumption of the business and is carried out by an authorised energy specialist. LED reduces the consumption for lighting and can be one of the recommended measures.

Last checked: 17 November 2026, Nick Cuppens, Clightstore. Sources: Asitis.cz, updated 27 October 2026, RAK HK (rakkhk.cz), 9 November 2026, Energylow.cz, 12 January 2026, Decree No. 183/2026 Coll. (esipa.cz) and Envispot.cz, 26 May 2026.

How much could your lighting save?

Send us the number and wattage of your current luminaires. We prepare a free DIALux lighting study and a no-obligation quote at direct-import prices, 2 to 4 times lower than comparable branded products.

Request a quote